| ISSUE 360/456 · PHYSICS |
~4 MIN |
FOUNDATION / GEOTHERMAL ENERGY · READING DATE 2027-09-26 · SEPTEMBER 2027 — EVIDENCE, CLIMATE AND ENERGY
Hot rock is a store; heat flow is a refill rate
START HERE
Rock beneath the ground can be hot enough to warm water passing through it. Geothermal heat flow is the rate of heat transfer from Earth’s interior toward the surface, usually stated per unit area. A large store of hot rock and a large continuing heat supply are related but different features of a resource.
|
/ WHY NOW
A hot borehole does not alone tell you how much useful heat can be removed year after year. Extraction depends on stored energy, replenishment, water movement and how well the rock transfers heat to the working fluid.
|
/ THE IDEA
Temperature describes how hot a material is, while thermal energy also depends on how much material is involved and its heat capacity, the energy needed per degree of warming. Heat flow describes the rate of transfer. In some regions, hot water moving through cracks carries heat; elsewhere, slow transfer through relatively still rock dominates. For a deliberately simple area budget, multiply average upward heat flow per square metre by the area feeding a resource. Suppose that entire flow enters our chosen store from below. This estimates continuing thermal power crossing its boundary. Extraction can temporarily exceed it by cooling stored rock, just as a reservoir can be drawn down faster than it refills. This is an accounting analogy, not a claim that heat moves like water through one pipe.
THE FORMAL IDEA
P_replenish = q × A; ΔE_store = (P_replenish − P_extract)Δt
| P values are thermal power in watts, joules per second; q is heat flow per area in W/m²; A is contributing area in m². | | Δ means change: ΔE_store is stored-energy change in joules and Δt is seconds. Using kilowatts, kW, and hours instead gives kilowatt-hours, kWh; 1 kWh = 3.6 million joules. A negative result means the store loses thermal energy. |
|
RUN THE TINY EXAMPLE
Change one thing. Predict what happens.
Toy region: q = 0.10 W/m² across A = 1,000,000 m². Replenishment power = 0.10 × 1,000,000 = 100,000 W = 100 kW. Extract 300 kW for one hour: store change = (100 − 300) × 1 h = −200 kWh. Change extraction to 150 kW: the one-hour drawdown becomes −50 kWh.
|
Lower extraction reduces depletion in this toy store but still exceeds the chosen replenishment rate. Neither number tells you the resulting temperature drop without knowing the participating rock and water’s heat capacity. A large store may support substantial output for a long time, while local cooling can still affect performance near a well.
/ SO WHAT?
Resource assessment combines temperatures with permeability, fluid supply, heat-transfer area and evolving output. Permeability is the ability of cracks or pores to let fluid pass through rock. A high-temperature site with poor fluid access can be harder to use than temperature suggests. Deep geothermal production also differs from shallow ground-source heat pumps, which move heat and need not tap a hot deep reservoir.
ONE CAVEAT |
| The heat flow and extraction numbers are invented, not typical values or a site assessment. Real replenishment is three-dimensional and time-dependent; reinjected water, pumping, chemistry and induced ground movement require specialist study. Thermal power is not automatically equal to electrical power. |
KEEP THIS
A hot resource can supply energy from its stored heat, but sustained extraction must account for how quickly that local store is replenished.
|
NEXT: A detectable change need not be a useful one
|